CDCP, CDCS, DCCA & Cisco CCT Data Center: practice drill
10 realistic exam questions, graded as you go, with the exact rule or statute citation for every answer. Start free, no sign-up.
Timed mock exam
16 questions in 19 minutes, drawn from every topic. No answers shown until the end, then a full score breakdown, your weakest topics and a review of what you missed.
Prices are in US dollars, plus tax where it applies. Stripe, our payment processor, calculates tax at checkout.
All sales are final. If something is really wrong, such as a duplicate charge or a purchase that does not unlock what you bought, write to support@careerexampro.com and we will put it right.
One-time payment. Nothing renews.
You have an exam ticket for this practice test. Start the timed mock exam to use it.
Exam Snapshot & Official Blueprint
Official Exam Fee
$125 (Pearson VUE / OnVUE)
Format & Time Limit
60–70 MCQs · 90 minutes (010-151 DCTECH)
Passing Standard
Scaled score (~790–825 out of 1000)
Typical Prep Incumbents
$250–$500 (Cisco Digital Learning)
Official Domain Breakdown
Exam Domain
Weight
Data Center Networking Fundamentals, Fiber Optics & Transceivers
On-Site Field Replacement, ESD Safety & Service Procedures
18%
High-Yield Formulas, Statutes & Rules Cheat Sheet
Fiber & Transceivers: Single-mode (OS2, yellow jacket, 9/125 µm, 1310/1550 nm, long reach, LR/ER optics) vs. Multi-mode (OM3/OM4 aqua, 50/125 µm, 850 nm, short reach, SR optics). Never mix APC (green angled) with UPC (blue flat) connectors.
Out-of-Band Management: Cisco IMC (CIMC), Dell iDRAC, and HPE iLO run on dedicated management NICs so technicians can inspect SEL hardware logs, mount virtual ISO media, and power-cycle hung servers even when the host OS is offline.
ESD & Hot-Swap Discipline: Wear a grounded ESD wrist strap on bare skin, pull dual-PSU/fan FRUs one at a time while verifying redundancy LEDs, and seat DIMMs/PCIe risers squarely to avoid bent socket pins.
Frequently Asked Questions
Is Cisco CCT Data Center (010-151) good for breaking into hyperscale data centers?
Yes—010-151 DCTECH directly validates hands-on field-technician skills: identifying optical transceivers, fiber polarity, server FRUs, RAID arrays, and out-of-band console recovery.
Exact question counts, passing scores, and allowed reference materials vary by testing window and state/agency. Always confirm current rules with the official testing provider.
Sample questions
Under EIA-310-D / IEC 60297 rack standards, what is the vertical height of one rack unit (1U), and where should the heaviest storage JBODs or rack-mount UPS units be installed inside a 42U cabinet?
1.75 in (44.45 mm); mount heaviest chassis at the bottom for stability.
2.00 inches (50.80 mm); mount the heaviest chassis at the top to aid natural convection cooling.
1.50 inches (38.10 mm); mount the heaviest chassis in the middle at 20U–24U for ergonomic access.
1.75 inches (44.45 mm); mount the heaviest chassis at the top so overhead cable trays support them.
Show the answer
A. 1.75 in (44.45 mm); mount heaviest chassis at the bottom for stability.
One standard rack unit (1U) equals 1.75 inches (44.45 mm), containing three mounting holes spaced across the rail. Heavy equipment (UPS modules, battery packs, dense storage enclosures) must always be mounted at the bottom of the rack to lower the center of gravity and prevent tip-over hazards when sliding rails out.
A database server runs a 6-drive RAID 6 array using 4 TB enterprise NVMe drives. Two drives fail over a holiday weekend before a technician arrives. What is the status of the array and its usable capacity?
The array has lost all data because parity arrays can only survive a single drive failure.
The array remains online in degraded mode with 20 TB usable capacity (one parity drive).
Online in degraded mode with 16 TB usable capacity (dual parity).
The array remains online in degraded mode with 12 TB usable capacity (mirrored pairs).
Show the answer
C. Online in degraded mode with 16 TB usable capacity (dual parity).
RAID 6 uses block-level striping with dual independent distributed parity (N - 2 usable capacity). With six 4 TB drives, usable capacity is (6 - 2) × 4 TB = 16 TB, and the array can tolerate up to two simultaneous drive failures while staying online in degraded mode.
Reference: SNIA Common RAID Disk Data Format (DDF) Specification — RAID 6
A storage node uses an 8-drive RAID 10 (1+0) array organized as four mirrored pairs. Drive 0 in Mirror Pair A fails and is not yet replaced. Which subsequent failure would cause immediate data loss?
Drive 2 failing in Mirror Pair B while Drive 0 is still offline.
Drive 4 failing in Mirror Pair C while Drive 0 is still offline.
Drive 6 failing in Mirror Pair D while Drive 0 is still offline.
Drive 1 failing in Mirror Pair A before Drive 0 finishes rebuilding.
Show the answer
D. Drive 1 failing in Mirror Pair A before Drive 0 finishes rebuilding.
RAID 10 stripes data across RAID 1 mirrored pairs. It can survive multiple drive failures ONLY if no more than one drive fails within any single mirrored pair. If both drives in Mirror Pair A (Drive 0 and Drive 1) fail simultaneously, the stripe is broken and data is lost.